College Physics ›› 2019, Vol. 38 ›› Issue (4): 50-53.doi: 10.16854 /j.cnki.1000-0712.180485

Previous Articles     Next Articles

Design of the visualization system of gas temperature   field based on schileren method

FAN Ke-zhou1,DENG Sen1,FAN Ze-tao1,FENG Wei-jie1,LI Jiao-yang1,2, WANG Jia-hui1,2 #br#   ,CAI Zhi-gang1,2   

  1. 1.School of Physics,Sun Yat-Sen University,Guangzhou,Guangdong 510275,China; 2.National Demonstration Center for Experimental Physics Education,Sun Yat-sen University, Guangzhou,Guangdong 510275,China
  • Received:2018-08-31 Revised:2018-11-02 Online:2019-04-20 Published:2019-05-10

Abstract: Schileren method is a practicable way whereby the change of medium refractive index can be visualized.

In this paper,optical devices incorporating beam splitter are utilized to design the split-folding light path and

solve prominently the low definition problem of the traditional light path. Meanwhile,the ghost interference is eliminated

by virtue of vertical reflection. Based on the optical path and MATLAB software,the knife-edge optimization

is actualized. Through the calibration experiment realized by blowpipe,the function between temperature and the

gray value of schlieren image provides a contactless solution to measure the airflow temperature,together with the

visualization system of gas temperature field.

Key words: schlieren method, split-folding, visualization, knife-edge optimization, airflow temperature